Sunday, September 8, 2019
Current legislation, standards and guidance require microbial Essay
Current legislation, standards and guidance require microbial monitoring of utilities (eg steam and water), facilities (eg the c - Essay Example The design of the sterile services department facility must be perfect in every detail to prevent microbial contamination of the area and the products. The entryway must be set up as to prevent unauthorised persons from gaining access and to stop workers from entering while wearing improper or insufficient protective clothing, since this traffic would bring outside contaminants into the sterile area. There must be space to separate sterilized equipment from contaminated equipment, so that no microbial cross-contamination occurs. Washrooms and changing rooms must be available to the staff and set up so that workers' outside clothing never comes into contact with their sterile gear (Sterile Services 2004). Due to the strenuous nature of these and dozens of other requirements, many hospitals and medical offices now choose to obtain their sterile equipment through a commercial retailer rather than have their own sterile services department on-site (Lawrence & May 2003). ... vel of particulate matter in the air is used to calculate the possible amount of microbial life present in the clean room facility, as well as dust and other contaminants such as ski and hair. (Rousseau 2004). It is monitored by a discrete-particle counter, which can detect particle diameters anywhere between 0,1 and 5 ?m to aid in determining the ISO clean room class of the facility (Schicht 2003). A sterile services department is required to contain the necessary equipment to disinfect medical products in an approved manner, following a validated sterilization process; the preferred method is steam sterilization (Russel, Hugo, & Ayliffe 1999). Steam sterilization is used because it is non-toxic and provides the most effective method for destroying many types of microbial life. Unfortunately, many contemporary surgical tools and medical devices are made of plastic, and would not survive a steam sterilization cycle. These items are decontaminated with a low-temperature method, such a s acid immersion (HIPAC 2008). Because many medical devices are considered critical risk, designed to come in contact with a patient sub-dermally, it is vitally important for a sterile services department to keep their sterilization equipment in perfect working order. The sterilizer itself must be tested daily to ensure it functions properly and completes an entire sterilization cycle, weekly for safety and function, and annually by a testing technician to check the steriliser against manufacturer specifications (Lawrence & May 2003). These tests help the sterile services department ensure that their sterilizer is actually removing the microbial load. Since the margin for error with sterilization is so narrow, a sterile services department must also ensure all incoming utilities, especially
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.